1Question: Wireless keypad fails to learn.  What do I do?

Answer

1. Check if the battery of the keypad is exhausted.

2. When the LED displays “Ln”, you should press the “ENTER” button once within 2 seconds to learn the keypad. If successful, the LED will flash “Ln” for 4 seconds. Default password is “888888”. You can press “* 8 8 8 8 8 8 ENTER” in sequence to operate the opener. for LM swing gate opener

When the REM LED light is on, you should press the “ENTER” button once within 2 seconds to learn the keypad. The REM LED light will flash for 4 seconds if learning has succeeded. Default password is “888888”. You can press “* 8 8 8 8 8 8 ENTER” in sequence to operate the opener. ( for DSD/C sliding gate opener )

3. Refer to the keypad manual, pull the antenna out and repeat “learn”.

2Question: Wireless keypad fails to change the password. What do I do?

Answer

1. The password of the keypad must be 6-digit code.

2. You can press “* 8 8 8 8 8 8 #” for LM105 or press “ * 8 8 8 8 8 8 * ” for LM172 in sequence to enter the changing password step.

The LED will display “CH” (new version from 2011) after this; press a 6-digit new password then press “#” for LM105 or press “*” for LM172 to confirm the operation. If successful, the LED will flash “CH” for 2 seconds and then back to “- -”. ( for LM)

The REM LED light will be on; press a 6-digit new password then press “#” to confirm the operation. The REM LED light will flash for 4 seconds if changing has succeeded. ( for DS)

 

3Question: I forgot the password of the wireless keypad 

Answer

You can re-learn the keypad to set the password back to factory default code(888888).

 

4Question: Gates won’t open or close properly after the push button is pressed 

Answer

1. Check if the wire connection is loose.

2. The push button has been failed. Please replace with a new one.

5Question : I install the loop detect and use it very well to open the get free of handbut the gate couldn’t closewhat do I do

Answer

Please set the automatic closing function in control board, ref to “Set the Automatic Closing Time” in Manual P.22, step 9. ( for LM )

Please set the automatic closing function in control board via turn the DIP Switch #6–#7, ref to “DIP Switch #6–#7: Auto close time of the gate operator” in manual. ( for DS )

 

6Question: Why is my electric lock not working after operation for a period of time?

Answer:

Firstly, make sure the electric lock well connected to the terminal “LOCK” on the control board. If it still does not work, please disassembled the e-lock and control board. Then check it by following steps:

1. Check the tongue of the lock whether it can slide smoothly forward and backward with no stucking.

2. If the tongue of the lock can slide smoothly, please use a multi-meter to measure the resistance of the e-lock. The resistance is about 8.0 Ω of 24V e-lock and 80 Ω of 36V e-lock. Please power the e-lock with the corresponding voltage if the resistance is correct. If it still does not work please replace a 24V solenoid.

3. If both of the solenoid and tongue of the lock are fine, please use a multi-meter to check if output of the ‘LOCK’ terminal on the control board is 24V at the beginning of the opening. If there is no output voltage, please replace the control board. The board is broken.